If Me.Caption Disconnect Then // Disconnect from the serial device. Note that these procedures only work if you don't have hardware flow control active. The following is the code I used which is from XOJO serial port routine. Windows users can refer here for a similar solution then coolterm gives a 103: Break Condition error and closes the connection. Make sure they are both set to the same baud rate and settings. Then, open two serial terminal windows (yes, you can have multiple terminal windows open at once), each connected to a different device. $ sudo interceptty -s 'ispeed 9600 ospeed 9600' /dev/pts/2 /dev/ttyUSB0įor this to work reliably, I have to run first the two instances of interceptty and then open the USB ports (in my case with minicom). Connect the TX line of one to the RX line of the other and vise versa. If Me.Caption Disconnect Then // Disconnect from the serial device SerialConnection1.Close Me.Caption Connect DevicesPopupMenu.Enabled True DeviceListUpdator. The following is the code I used which is from XOJO serial port routine. There are large differences among approaches depending on sensing techniques and sensors, breathing parameters, sensor locations, system setups, communication. Even when i press RESET button on Nucleo board, then i can connect to port again and it works. An error occurred while reading the data from the device. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators. But there are some exclusion: Serial port can be opened only when i running code from IDE. This is an example of what I capture writing on port 0 and port 1 with minicom: > 0x48 (H)įor your particular case, you only have one port on your computer, so you can create the virtual port pair with just one link: $ sudo socat -d -d pty,link=/dev/ttyUSB0,raw,echo=0 pty,raw,echo=0Īnd run two sessions of interceptty: $ sudo interceptty -s 'ispeed 9600 ospeed 9600' /dev/pts/1 /dev/ttyUSB0 In most cases serial port can't be opened via almost all terminal apps (i use CoolTerm, putty, own QT-based serial monitor). Plug into USB port and open connection in CoolTerm. I will now see all data traveling on the bus. Connect the XBEE you want to program to the xbee xplorer. You can view various parameters, such as the SSID, channel, IP address, serial port, and other settings, and configure them in command mode. This is the output I get (note the names of the virtual devices created): 3 08:23:32 socat N PTY is /dev/pts/1ģ 08:23:32 socat N PTY is /dev/pts/2ģ 08:23:32 socat N starting data transfer loop with FDs and Īnd then I can run interceptty on a third terminal: $sudo interceptty -s 'ispeed 9600 ospeed 9600' /dev/pts/2 /dev/ttyUSB1 RTS and DTR need to both be OFF for proper serial connection. I did not even think of RTS and DTR, but that was it. Programming worked like a charm, but serial was simply dead. Now, if I want to snif on this link I can do the following: first I create a couple of virtual serial ports and link them to my real ports: $ sudo socat -d -d pty,link=/dev/ttyUSB0,raw,echo=0 pty,link=/dev/ttyUSB1,raw,echo=0 I experienced the same with the ESP32-CAM-MB - module. I can open two terminals and send text from port 0 to port 1 or viceversa with minicom or any other terminal utility. CoolTerm is portable and includes a built-in help file. When you break a programming problem down into smaller pieces, be sure. I have linked them together with wires: RX on port 0 goes to TX on port 1, port 0 TX goes to port 1 RX. CoolTerm is a serial port terminal application for those the need to exchange data with hardware connected to serial ports, such as servo controllers, robotic kits, GPS receivers, microcontrollers, etc. E23C450A19D2370400BB5C65 /* CLTAppDelegate.In my setup, I have two real (well, they are actually USB-to-serial adaptors) serial ports on /dev/ttyUSB0 and /dev/ttyUSB1.
0 Comments
Leave a Reply. |